Reading the status
The dashboard answers two separate questions, and keeps them apart on purpose.
Is the sensor working?
Does the filter need changing?
After you change the filter
On My System, tap I put in a new filter. That starts the count for the new filter, so its age and runtime start from zero. It takes two taps on purpose.
The clean-filter reading your system learned stays in place. If the new filter reads differently, K&H updates it.
What's on the dashboard
One number: filter life remaining. 100% is a clean filter on your own system, 0% is the point where it should be changed. Beside it, the filter picture fills with dust to match, measured against that same change point. The chart underneath is the same number over time, with a dashed line showing where it's heading.
Everything else is optional. Tap Settings (top right) to switch on the technical readings, the duct schematic, the ΔP and air-temperature charts, or a list of every sensor — and to open the reading log. Nothing you turn on there changes the sensor; it only changes what this browser shows you.
Why does it say it's still learning?
Every home's ductwork is different, so the sensor first has to learn what your system reads with a clean filter. It measures across several separate heating or cooling cycles before it says anything about the filter.
Nothing is wrong while this shows. The sensor is reporting normally; it's just refusing to guess. Once the clean reading is confirmed, the filter life number and status colours appear on their own.
What does the clean-filter resistance note mean?
Pressure across your filter was high even when it was clean. That doesn't mean the filter is dirty, and the monitor still tracks changes from that clean reading.
Several things can cause it. Email K&H if you'd like us to review the installation.
Common problems
A sensor says "Not reading".
It has stopped sending data — usually Wi-Fi, or power to the unit. Check that it has power and that your Wi-Fi is up. If it doesn't come back, email K&H. Your filter reading beside it is simply the last one it managed to send.
It says "waiting for first reading."
The sensor is registered but hasn't posted yet — it's booting or joining Wi-Fi. Live data appears the moment it sends.
The reading shows 0 (or nearly 0).
The furnace/AC blower is off, so no air is moving and there's no pressure to measure. It jumps back to a real number the moment the system runs.
The page won't load on my phone.
Check that other sites load, then refresh. If it still won't load, email us the page address and what you see.
How the estimate works
A small sensor sits across your furnace filter and measures the pressure drop — how hard the blower has to pull air through the filter. A clean filter is easy to pull air through; a loaded filter fights the airflow, and the pressure drop climbs.
The sensor learns your system's own clean-filter reading after it's installed. From then on it compares every reading to that clean baseline; the further above baseline it climbs, the more loaded the filter is.
It answers "when do I change it?" three ways at once, and tells you whichever comes first: the pressure trend (a filter loading up), blower runtime (how long this filter has actually run compared to your last one), and plain age (some filters wear out before their pressure ever moves).
Readings post to this dashboard automatically over Wi-Fi.
Changing the numbers yourself
Under Settings, Advanced calibration holds the values the dashboard judges by: the change point (how far above the clean reading counts as "replace it" — a rise of 0.15 in.w.c. by default), the caution point (a rise of 0.10 by default), the change-by-age backstop (90 days by default — some filters wear out before their pressure ever moves), and the blower-on threshold below which a reading counts as "the system is off". Move them and the percentage, the colors, and the chart all follow in this browser. The reset button puts them back.
Contact K&H
Email hello@kh-sensors.com. A sensor that stops reading, a page that will not load, a question about what the number means: email us and we'll help.
What the triangle (Δ) means
Δ
The triangle is the Greek letter delta. In engineering it means "change" or "difference." So ΔP ("delta-P") is the difference in pressure across the filter — the air pressure on one side minus the pressure on the other.
A clean filter has a small ΔP. As dust builds up, air can't pass as easily, so the pressure difference across it grows. That growing ΔP is exactly what tells you the filter is loading up.
The Filter Index is just that pressure drop shown as an easy number — switch on "Technical readings" in Settings to see it. The higher it climbs above where it started clean, the more loaded the filter.